Series 50 Fixed Light unit

Description

An extremely strong fixed panel incorporating a 30mm glazing rebate designed for security applications and suitable for use as vision panels in controlled environments. The ability to accept thicker glass or sealed units also allows for improved acoustic or thermal insulation. Glazing must be specified in accordance with BS6262:2005 'Codes of Practice - Glazing for Buildings'
Options include trickle ventilators fitted within a separate timber head and acoustic reveal linings to head and jambs.
All fixings are concealed within the frame.

Size guidelines

Maximum: 1500mm x 3000mm
Minimum: 400mm x 400mm

Performance

Physical security- LPS 1175 SR1 and SR2 / BS 7950 Secured by Design
Blast – DIS 16933 Explosion protection rating EXV25(c)
Acoustic- Rated in accordance with BS EN ISO 717-1
Refer to Selectaglaze for details

Specification

Manufacturer: Selectaglaze™ Ltd. Campfield Road, St. Albans, Hertfordshire, AL1 5HT. Tel: 01727 837271. Fax: 01727 844053. Email: enquiries@selectaglaze.co.uk Web: www.selectaglaze.co.uk
Product reference:
Series 50 Fixed

Frames

Aluminium extruded from 6063T6 alloy

Finish

HIPCA White 9910 semi-gloss Polyester Powder Paint to BS 6496:1984
RAL colour Polyester Powder Paint / Anodised silver AA10 / Anodised bronze AA25

Glazing

6mm to 12mm / 24mm sealed units

Ironmongery / Accessories

Acoustic lining:- Mineral fibreboard / pvc faced acoustic foam / Rockwool filled perforated metal trays

Fixing

Structural fixings:- locally specified to suit security rating
Frame fixings:- Aluminium cleats
Grounds:- none
Sealants:- frames bedded in acrylic compound

Black – standard specification Red – Optional specification