Selectaglaze secondary glazing
Selectaglaze Ltd, Campfield Road, St. Albans, Hertfordshire AL1 5HT
Phone 01727 837271   Fax 01727 844053
The leading secondary glazing specialists
 
   

Rw dB values for Selectaglaze Secondary Glazing Systems

 

Secondary Glazing

Series 10 HS

Series 20 VS

 Series 30 LO

Series 40 SHC

Series 40 DSH

Series 40 FL

Series 45 SHC

Series 45 DSH

Series 45 FL

Series 46FL

Series 50 SHC 

 Series 50 FL

Series 55 DFL 

 Series 60 TVS

Series 80 HS 

Series 85 SHC 

Series 90 VS 

 Series 95 VS

 4mm

 45

 45 

 44

 47 

 45

 47 

 47

 45

 47

 

 

 

 

 46

 

 

 

 

 6mm

 45

 45

 44

 47

 45

 47

 47

 45

 47

 47 

 46

 47

 

 46

 46

 

46 

 

 6.4mm

 45

 45

 44

 47

 45

 47

 47

 45

 47

 

 

 

 

 46

 46

 

 46

 

 6.8mm

 46

 46

 45

 48

 46

 48

 48

 46

 48

 

 

 

 

 47

 47

 

 47

 

 7.5mm

 

 

 

 48

 46

 48

 

 

 

 

 47

 48

 46

 

 47

 

 46

46 

 8mm

 47

 47

 46

 49

 47

 49

 49

 47

 49

 

 

 

 

 48

 48

 

 48

 

 8.8mm

 

 

 

 49

 47

 49

 

 

 

 

 

 

 

 

 48

 

 48

 

 9.5mm

 

 

 

 49

 47

 49

 

 

 

 49

 48

 49

 47

 

 48

 47

 48

 47

 10mm

 

 

 

 49

 47

 49

 

 

 

 

 

 

 

 

 48

 

 48

 

 10.8mm

 

 

 

 50

 48

 50

 

 

 

 

 49

 

 

 

 49

 

 48

 

 11.5mm

 

 

 

 50

 48

 50

 

 

 

 50

 49 

 50

 48

 

 49

 48

 49

 48

 12mm

 

 

 

 50

 48

 50

 

 

 

 

 

 

 

 

 49

 

 48

 

 Key:  HS - Horizontal sliding, VS - Vertical sliding, TVS - Tilt in vertical sliding, SHC - Side hung casement, DSH - Double side hung, LO - Lift out, FL - Fixed light, DFL - Demountable fixed light.

Test Standards

Selectaglaze secondary window systems have been tested at the Taylor Woodrow Technology Centre in accordance with BS EN ISO 140-3:1995 'Laboratory measurement of airborne sound insulation of building elements'.  Certificate of Test Number 8049 - March 2006.

The results have been interpreted by Hann Tucker Associates, consultants in acoustics, to extrapolate and interpolate sound reduction values for the full range of Selectaglaze products.  The table shows results for secondary windows set at a 200mm cavity with 6mm float glass in the primary window.  Figures are available for cavities set at 50mm, 100mm or 150mm and also 1/3 octave Sound Reduction Index (R) values for each test. 

 

Selectaglaze systems used in Control Rooms or as part of a triple glazed assembly have achieved reductions up to 56 dB.       